CBLLP - LUNG DIFFUSION GAS MIXES

  • MSDS: CBLLP
  • Manufacturer: NATIONAL WELDERS
  • Product Name: LUNG DIFFUSION GAS MIXES
  • National Stock Number: 6830-00N070262
Product Identification

Product ID:LUNG DIFFUSION GAS MIXES
MSDS Date:01/01/1991
FSC:6830
NIIN:00N070262
MSDS Number: CBLLP

Responsible Party
NATIONAL WELDERS
CHARLOTTE, NC 28231
US

Emergency Phone: 800-866-4422;800-424-9300(CHEMTREC)

Info Phone: 704-333-5475

Cage: 18264

Contractor
NATIONAL WELDERS SUPPLY CO INC
31007 CHARLOTTE, NC 28231 US

Telephone: 704-333-5475

Cage: 18264

Ingredients

1,000 - 5,000 MOLAR PERCENT.

CAS: 630-08-0

RTECS: FG3500000

Fraction By Weight: <0.1%

OSHA PEL 50 PPM

ACGIH TLV: 25 PPM


OXYGEN

CAS: 7782-44-7

RTECS: RS2060000

OSHA PEL N/K

ACGIH TLV: N/K


10 MOLAR PERCENT.

CAS: 7440-59-7

RTECS: MH6520000

Fraction By Weight: 10%

OSHA PEL N/K

ACGIH TLV: N/K


CARBON DIOXIDE

CAS: 124-38-9

RTECS: FF6400000

Fraction By Weight: TRACE

OSHA PEL 5000 PPM

ACGIH TLV: 5000 PPM;30000 STEL


NEON

CAS: 7440-01-9

RTECS: QP4450000

Fraction By Weight: TRACE

OSHA PEL N/K

ACGIH TLV: ASPHYXIANT


ACETYLENE

CAS: 74-86-2

RTECS: AO9600000

Fraction By Weight: TRACE

OSHA PEL N/K

ACGIH TLV: ASPHYXIANT


NITROGEN

CAS: 7727-37-9

RTECS: QW9700000

Fraction By Weight: BALANCE

OSHA PEL N/K

ACGIH TLV: ASPHYXIANT


REMOVAL FROM CONTAM AREA IS MOST IMPORTANT.

RTECS: 9999999ZZ


ARTF RESP & OXYG AT SAME TIME. ADMIN OF OXYG AT

RTECS: 9999999ZZ


HAS TREATMENT IN HYPERBARIC CHAMBER. MD SHOULD BE

RTECS: 9999999ZZ


DISCHARGE RATE OF PROD FROM CYL. USE CHECK

RTECS: 9999999ZZ


CYL. PROT CYLS FROM PHYSICAL DMG. STORE IN COOL,

RTECS: 9999999ZZ


& EMER EXITS & AWAY FROM FULL/EMPTY STORED CYLS

RTECS: 9999999ZZ


STORED TO EXCEED 130F (54C). CYLS SHOULD BE STORED

RTECS: 9999999ZZ


OVER. FULL/EMPTY CYLS SHOULD BE SEGREGATED. USE

RTECS: 9999999ZZ


BEING STORED FOR EXCESSIVE PERIOD OF TIME. FOR ADDNL

RTECS: 9999999ZZ


PAMPHLET P-1. THESE GAS MIXTS CAN BE HNDLD IN MOST

RTECS: 9999999ZZ


CONTENT MIXTS MUST BE "CLEANED FOR OXYG SERVICE".

RTECS: 9999999ZZ


CYLS SHOULD NOT BE REFILLED EXCEPT BY QUALIFIED

RTECS: 9999999ZZ


CYL WHICH HAS NOT BEEN FILLED BY OWNER/WITH HIS

RTECS: 9999999ZZ


USE PROD IF COMPONENT CONC DATA IS NOT CLEARLY

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CARBON MONOXIDE:DEPENDING ON LEVELS &
DURATION OF EXPOS, SYMPS MAY INCL HDCH, DIZZ, HEART PALPITATIONS,
WEAK, CONFUSN & NAUS TO CONVLS, EVENTUAL UNCON & DEATH. BECAUSE IT
IS COLORLESS & ODORLESS POIS GAS, THERE IS NO WARNING OF ITS
PRESENCE OTHER THAN ABOVE SYMPS. ANALYTICAL MONITORS, W/ALARMS,
SHOULD (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:BE EMPLOYED WHERE POSSIBILITY OF RELS
OF TOX QTYS EXISTS. OXYG TRANSPORT FUNC OF HEMOGLOBIN OF BLOOD IS
REDUCED SINCE IT REACTS W/INHALED CARBON MONOXIDE TO FORM CARBOXY
HEMOGLOBIN INSTEAD OF ITS NORMAL RXN W/OXYG IN LUNGS TO
FORMOXYHEMOGLOBIN. AFFINITY OF HEMOGLOBIN FOR CARBON MONOXIDE IS
200-300 (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:PROMPT MED ATTN IS MANDATORY IN ALL CASES OF OVEREXP TO
CARBON MONOXIDE. RESCUE PERS SHOULD BE EQUIPPED W/NIOSH/MSHA APPRVD
SCBA. INGEST:CALL MD IMMED . EYES:IMMED FLUSH W/POTABLE WATER FOR
MIN OF 15 MINS, SEEK ASSISTANCE FROM MD SKIN:FLUSH W/COPIOUS AMTS
OF WATER. CALL MD . INHAL:CONSCIOUS PERS SHOULD BE ASSISTED TO
UNCONTAM AREA & BE TREATED W/SUPP OXYG. QUICK (ING 8)

Fire Fighting

Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE . NONFLAMMABLE
GAS MIXTURE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .

Accidental Release

Spill Release Procedures:EVACUATE ALL PERS FROM AFFECTED AREA. USE
APPROP PROT EQUIP. IF LEAK IS IN USER'S EQUIP, BE CERTAIN TO PURGE
PIPING W/INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN
CNTNR/CNTNR VALVE, CONT YOUR CLOSEST SUPPLIER LOCATION/CALL EMER
(SUPP DATA)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:VALVE PROT CAPS & VALVE OUTLET
THREADED PLUGS MUST REMAIN IN PLACE UNLESS CNTNR IS SECURED W/VALVE
OUTLET PIPED TO USE POINT.
Other Precautions:USE ONLY IN WELL-VENTED AREAS. DO NOT DRAG,
SLIDE/ROLL CYLS. USE SUITABLE HAND TRUCK FOR CYL MOVEMENT. USE
PRESS REDUCING REGULATOR WHEN CONNECTING CYL TO LOWER PRESS (<3,000
PSIG) PIPING/SYS. DO NOT HEAT CYL BY ANY MEANS TO INCR (ING 11)

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED POSITIVE PRESSURE AIR LINE
RESPIRATOR W/MASK OR NIOSH/MSH APPROVED SELF-CONTAINED BREATHING
APPARATUS SHOULD BE AVAILABLE FOR EMERGENCY USE.
Ventilation:LOCAL EXHAUST: TO PREVENT ACCUMULATION ABOVE TWA FOR CARBON
MONOXIDE.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . SAFETY SHOES.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
APPEAR/ODOR:ETHEREAL/GARLIC-LIKE ODOR. SPILL PROC:TELEPHONE # LISTED
HEREIN. WASTE DISP METH:TELEPHONE # LISTED HEREIN. EFTS OF
OVEREXP:TIMES GREATER THAN ITS AFFINITY FOR OXYG. ALL OF DISORDERS
ARE D UE TO MARKEDLY REDUCED CELLULLAR RESP &MAY INCL CNS
IMPAIRMENT, CVS COLLAPSE, RENAL INSUFFICIENCY, COMA, ETC.

Chemical Properties

Solubility in Water:GAS MIXTURE
Appearance and Odor:COLORLESS, ODORLESS GAS UNLESS IT CNTNS ACETYLENE
WHICH HAS DISTINCTIVE (SUPDAT

Stability

Stability Indicator/Materials to Avoid:YES

Disposal

Waste Disposal Methods:DO NOT ATTEMPT TO DISP OF WASTE/UNUSED QTYS.
RETURN IN SHIPPING CNTNR PROPERLY LABELED, W/ANY VALVE OUTLET
PLUGS/CAPS SECURED & VALVE PROT CAP IN PLACE TO YOUR SUPPLIER. FOR
EMER DISP ASSISTANCE, CONT YOUR CLOSEST SUPPLIER LOCATION/CALL
EMER (SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.